    The primary of a winding transformer has 400 turns while the secondary has 2000 turns. If the power output from the secondary at 1000 V is 12 kW, what is the primary voltage?

    A) 200V

    B)        300V

    C) 400V    

    D) 500V

    Correct Answer: A

    Solution :

    [a] \[{{N}_{P}}=400,\,n={{N}_{S}}=2000\,{{V}_{S}}=1000\,V.\] \[\frac{{{V}_{p}}}{{{V}_{S}}}=\frac{{{N}_{p}}}{{{N}_{s}}}\]of \[{{V}_{p}}=\frac{{{V}_{S}}\times {{N}_{P}}}{{{N}_{S}}}=\frac{1000\times 400}{2000}=200\,V\]