CEE Kerala Engineering CEE Kerala Engineering Solved Paper-2010

  • question_answer
    A carrier frequency of 1 MHz and peak value of 10 V is amplitude modulated with a signal frequency of 10 kHz with peak value of 0.5 V. Then the modulation index and the side band frequencies respectively are

    A)  0.05 and 1 ± 0.010 MHz

    B)  0.5 and 1 ± 0.010 MHz

    C)  0.05 and 1 ± 0.005 MHz

    D)  0.5 and 1 ± 0.005 MHz

    E)  0.05 and 1± 0.100 MHz

    Correct Answer: A

    Solution :

    Modulation index\[=\frac{{{A}_{m}}}{{{A}_{c}}}=\frac{0.5}{10}=0.05\] Band frequencies \[=1\text{ }MHz\pm 10\text{ }kHz\] \[=1\text{ }MHz\pm \frac{10}{1000}MHz\] \[=1\text{ }\pm \text{ }0.01\text{ }MHz\]